Material
The Custom Fiberglass Products tank shall be constructed of glass reinforced solid laminated plastic, the ultimate insurance against possible leaks. The durable material requires no maintenance, is lighter in weight than steel or aluminum This material used is high-impact resistant wax free polyester resin.

Shell
Shell is one piece seamless female vertical wall molded with all exterior longitudinal corners having 1" radius. All 3/8" floor with 5/16" bulkheads and sides reinforced and tested for integrity and ZERO leakage. Outside flange design for fully removable lid design. Exterior is red in color.

Baffles
Baffle partitions shall be constructed of reinforced 5/16" POL-E material. Main baffle partition shall be a one piece design and extend from front to rear of the tank. All baffle partitions are reinforced and integrated to side walls to provide greatest strength and allow maximum air and water flow, minimum surging, and to comply with NFPA 1901. Main baffle shall be reinforced to tank walls, floor and lid.

Fully Removable Lid
The lid shall be a bolt down fully removable and designed to allow full access to the tank. Lid will be 5/16" composite laminate reinforced construction. Lid is bolted in place with stainless steel bolts, with no part of the bolts making contact with the tanks contents. Bolts are located on 4" centers around full lid perimeter and transverse baffle on 8" centers. Lid is sealed with a full perimeter closed cell neoprene gasket. Exterior is red in color.

Fill Tower
The fill tower shall be 9" square with hinged, spring loaded access lid with a plastic screen strainer.

Overflow
There shall be a 3" ID overflow pipe installed from the fill tower to the bottom of the tank. The overflow pipe shall be sch 40 with discharge to beneath tank through floor.

Couplings
All threaded couplings shall be CFP's special PVC schedule 80 pipe fittings. Each coupling shall be bonded to the tank shell. All intakes shall have a pressure deflector bonded to the back side to direct pressure away from partitions and reduce agitation.

Air Vent
There shall be an air escape venting in the tank to allow maximum fill capacity should the vehicle be parked on unlevel ground.

Sight Level
There shall be a sight level on one side of the rear of the tank. The sight level shall be a series of slots or recessed tube from the top to the bottom of the tank allowing the water level inside the tank to be seen without the assistance of electrical instruments. Sight level glass cleanout plug standard.

Sump Area
Sump area will be located near the center and at the rear of the tank with the suction connection plumbed in with oversized pipe. An anti-swirl baffle that functions like a low level strainer is installed to insure the strong non-cavitating operation of the pump.

Pump Platform
The pump platform will be made of non-corrosion FRP sheet material with two structural FRP 4' high I-beams located to support the deck and provide a space under the deck for tool storage. A tool stop is located at approx. 6" from rear to keep tools in easy reach. A red/white strip of scotchlite reflective tape is affixed to a rear deck flange for nighttime visibility.

Mounting
Each skid will have a procedure for mounting depending on the design that is chosen and the vehicle that it will be mounted on. Mounting procedures are to be approved by CFP prior to delivery. Clip angles, springs and washers supplied (bolts, length ?, by Fire Department)

Pump Model
The pump shall be a ___ model ___ with a ___ engine and ___ or electric start/stop and a manual throttle located on the pump with ___ gallon fuel tank and hose.

Pump Performance
___ GPM @ ___ PSI
___ GPM @ ___ PSI
___ GPM @ ___ PSI

Battery
(Optional - Suggest using battery system on P/U Truck). This eliminates running pump dry to charge pump battery.

Primer
The pump shall be equipped with an exhaust type primer system which uses the __ HP engines cylinder to develop vacuum.

Pump Panel
There shall be a lighted ___ pump mount panel with gauge.

Valves
All suction and discharge valves shall be ___ or equal ___ psi double seat bronze swing out ball valves.

Suction
There shall be a ___" suction connection located at the pump operator's area facing rear with a ___" FNST chrome swivel supplied with a plug. There shall be a ___" tank to pump valve located behind the pump operator's area.

Discharge
There shall be a pump manifold system with one ___" NSTM discharge valve and fitting. There shall be a ___ " tank fill valve, and ___ " valve for the ___. All of the above installed as needed with flexible connections from the manifold to the (real, tank, etc.) components.

Garden Hose Spigot (Optional or Supplied)
3/4" bronze spigot for garden hose discharge ___.

Hose Reel (Optional or Supplied)
One ___ or 12 volt electric rewind ___ hose reel is a ___ reel to hold ___' of ___" booster hose. Reel will be reconnected to pump with ___" hose and mounted to tank lid. Manual rewind crank included, with high rollers and guides on both sides of reel.

Hose Tray (Optional or Supplied)
FRP hose tray or ___ trays may be run transverse on tank at front, side or back of tank and is designed to hold ___' of ___" hose. A ___" discharge valve is located at pump or ___ pre-connect piped to hose tray.

Warranty
The tank shall be issued a Custom Fiberglass Products Unlimited Time (lifetime+) with $200 dollar per day out of service Warranty. Pump warranty is one year from pump manufacturer and engine warranty from engine manufacturer. Valves are warranted 1 year by valve manufacturer. Reel is warranted for 1 year from reel manufacturer.